Programming Symbol Barcode Scanner Home Search Article Links

Home
Up
Downloads
Links & FAQ
Suggestions
Manuals
What's New
Submit Solutions
Products

Programming Symbol P360 and P 470 Barcode Scanner

Symbol P360

Make sure you charge the scanner for about 24 hours before portable use.

The complete manual for the scanner should be available as a PDF file on the CD-ROM accompanying the item. Also available at Symbol's website.

You will need to print out pages entitled:

Enable/Disable Interleaved 2 of 5 (approx. page 5-54 or 92 of 146)

Set Lengths for Interleaved 2 of 5 (approx. page 5-56 or 94 of 146)

*page numbers may vary depending on date of manual and Adobe Acrobat page settings. Check Title of Page.

There are two major steps to configuring the P360 to function according to Compulink's specifications.

1) Enable Interleaved 2 of 5, any length barcodes:

- Press Func , * , Func , BK until you see Phaser Setup menu. Scroll down using arrow keys or press 2 to enter Parameter Control. Press ENTER.

- You must now scan the following barcodes in the manual to enable interleaved 2 of 5.

Scan Barcode entitled: ENABLE INTERLEAVED 2 of 5 (page 5-54  or 92 of 146)

Scan Barcode entitled: 2 of 5 - ANY LENGTH (page 5-56 or 94 of 146)

- Press Func, BK to return to main.

2) Set Carriage Return

- Press Func , * , Func , BK until you see Phaser Setup menu.

- at 0. System Setup, press ENTER

- Scroll down or press 5. Set Scan Options. Press ENTER

- Scroll down or press 3. Data Suffix. Press ENTER.

- Press Func, BK to return to main.

Your Scanner should now be ready for scanning.

Download the P360 scanner manual here

To enter multiple quantities in inventory , press the  [* + (quantity) + ENTER without the plus signs] on the keypad of the scanner prior to scanning the item. example: * 15 ENTER (scan)

 

Programming Symbol P470 / 370 (k370) wireless scanner

Compulink Programming Sheet for K370 KBW

Compulink Programming Sheet for K370 USB and KBW

P470 / 370 manual

Set Synapse Defaults

  1. Scan "Set all defaults" on page 75 of 202 (book 5-7)
  2. Scan "Set Synapse PC Wedge Defaults" (Synapse Smart cable guide)
  3. Host Selection: "IBM PC/AT" (Synapse Smart cable guide)
  4. Suffix Value: scan "ADF Rules" ASCII value 7013, 1 through 9 and "reset Scanner" on page 48 of 202 and 49 of 202 (book 3-18 and 3-19)
  5. Scan "Enable Interleaved 2 of 5" on page 126 of 202 (book 5-58)
  6. Set Lengths for Interleaved 2 of 5: scan "I 2 of 5 - Any Length" on page 128 of 202 (book 5-60)
  7. Recycle the power by powering down the scanner, taking the power cable out of the cradle and power back up by reinserting.

Your scanner is now up and running.

Troubleshooting:

bulletIf your scanner is not pairing and displays the message "communication failed", make sure the unit and the cradle are powered and try again. If they are powered and you are still unsuccessful, unplug all the cables from the cradle and try the barcode on the side of the scanner to pair the units.  A successful pair means the scanner will beep and will not display any error messages.  In order to test the scanner, open Windows Notepad and try to scan any frame barcode.  A successful scan will display the numbers on the screen and will drop to the next line for any scans after.
bulletRecycle the power on the unit before and after reprogramming.

NOTE: To enter multiple quantities in inventory , press the  [* + (quantity) + ENTER without the plus signs] on the keypad of the scanner prior to scanning the item. example: * 15 ENTER (scan)

    

Questions or problems regarding this web site should be directed to Michael A.
Copyright © 2009 Compulink Business Systems. All rights reserved.